More and more safety boots carry an ESD marking, and some site rules now ask for it. But ESD is often confused with “antistatic” and even with protection against electric shock. Here is what ESD actually means, who needs it, and what it does not do.

What ESD means

ESD stands for electrostatic discharge. When you walk, your body builds up a static charge. Touching a sensitive electronic component can discharge it in a fraction of a second – too small to feel, but enough to damage circuit boards, sensors or control electronics.

ESD footwear lets that charge flow to the floor in a controlled way, so it never builds up. It is mainly about protecting products and equipment, not the wearer.

ESD vs antistatic: the numbers

Both properties are defined by the electrical resistance of the shoe, but the ranges are different:

  • Antistatic (A) under EN ISO 20345: 100 kΩ to 1000 MΩ (1 GΩ). All safety footwear of class S1 and above must meet it, so every S1, S3 or S7 boot is antistatic.
  • ESD under EN 61340-5-1: the shoe must stay below 100 MΩ when tested to EN 61340-4-3. In addition, the whole system of person, shoe and floor is typically checked to stay below 35 MΩ.

The ESD range sits inside the antistatic range. That means every ESD shoe is antistatic, but not every antistatic shoe is ESD. A boot measuring 500 MΩ is antistatic but far too resistive for an electronics area.

ESD compliance is shown with a separate ESD symbol on the shoe or label, next to the EN ISO 20345 marking. If the product only says S3 or S3S without ESD, treat it as antistatic only.

Who needs ESD safety shoes

  • Electronics production, assembly and repair – circuit boards, control units, sensors.
  • Work inside an ESD Protected Area (EPA), where the site has a formal ESD programme.
  • Installation and service work in rooms with sensitive equipment when the client’s site rules require ESD footwear.
  • Laboratories and clean areas that specify ESD.

On a normal construction site, ESD is not required. Antistatic S3 boots are the standard. ESD does no harm on site, so if your crew moves between construction and electronics or technical rooms, an ESD boot covers both.

What ESD shoes do NOT do: electricians, read this

ESD and antistatic shoes are not electrically insulating. They are designed to let charge flow through, so they offer no protection against electric shock from mains or other AC/DC voltages. An electrician doing live work needs electrically insulating footwear under EN 50321-1, which is a completely different product, together with the other measures required for live working.

For most electricians on a construction site, the right choice is a normal S3 or S3S boot. Choose ESD if you also work on electronics or in areas with ESD rules.

Keeping ESD shoes working

The resistance of a shoe is not fixed. It can change with:

  • Dirt on the sole or contact areas – clean the sole regularly.
  • Temperature – shoes left in a cold car overnight may measure higher until they warm up.
  • Insoles – in an ESD shoe the insole is part of the electrical path. Only use insoles approved for that model. More in our safety boot fit guide.
  • Wear and damage to the sole.

Many EPA areas have a tester at the entrance. Check your shoes there. If they fail, clean them, let them warm up and test again before assuming they are faulty.

ESD models in our range

All models are in the safety boots collection. For toe cap and midsole choices, see composite vs steel toe caps. Ordering for a team? Use the workwear kit builder.

FAQ

Is ESD the same as antistatic?

No. Antistatic covers 100 kΩ to 1000 MΩ; ESD requires a lower resistance (below 100 MΩ). Every ESD shoe is antistatic, but not the other way round.

Do ESD shoes protect against electric shock?

No. They conduct charge on purpose. For live electrical work you need insulating footwear under EN 50321-1.

Do I need ESD boots on a construction site?

Usually not. Antistatic S3 boots are standard. ESD is needed when you work in electronics areas or the client’s site rules require it.

Can ESD shoes stop working?

Yes. Dirt, wrong insoles, damage and cold can raise the resistance. Keep them clean, use approved insoles and test them where the site has a tester.